Home›The Treatise›Chapters›Chapter 10
Tratado de Cirurgia da Coluna Vertebral
SECTION 1 • Basic Concepts
Chapter10

Biomechanics of Implants in Spinal Fixation

Vancouver: Martins DE, Parreira MGC📖 Pages: 119-134
Full reading of this chapter is available exclusively in the printed edition of the Treatise.
Sec. 1Basic Concepts
Cap. 10Clinical Chapter
2authors
Português
Español
English
Referênciasscientific citations
📑

Chapter Summary

• Context: Spinal fixation must provide immediate rigid structural stability, maintain or restore physiological multiplanar alignment, shield healing bone grafts from destructive shear and tensile stresses, and resist mechanical fatigue failure until solid biological arthrodesis is achieved. The biomechanical performance of a spinal construct results from the complex interplay of implant biomaterials (titanium alloys, cobalt-chromium, stainless steel, PEEK, silicon nitride, porous 3D-printed titanium), geometric structural design (screws, rods, hooks, wires, plates, interbody cages), bone-implant interface anchorage, and global load sharing. Pedicle screws achieve three-column purchase by anchoring into the cortical pedicle walls and cancellous vertebral body. Their pullout strength, toggle resistance, and fatigue life depend on outer diameter, pitch, thread design (cylindrical vs. conical), insertion depth, trajectory (anatomical vs. cortical bone trajectory [CBT]), and local bone mineral density (BMD). Spinal rods must balance flexibility for contouring with fatigue resistance and stiffness (stiffness ranking: CoCr > stainless steel > Ti alloy > PEEK). Interbody cages reconstruct the anterior load-bearing column, restore disc height and indirect foraminal decompression, and mitigate posterior hardware stress. Understanding construct rigidity, stress shielding, crosslink connectors, junctional stress transfer, and salvage techniques for osteoporotic bone (cement augmentation, bicortical purchase) is essential for avoiding catastrophic implant failure, screw loosening, rod breakage, and proximal junctional failure (PJF).
• Chapter Objective: To present the biomechanical fundamentals of spinal instrumentation and analyze the mechanics of pedicle screws, rods, hooks, wires, plates, and interbody cages. The reader should be able to understand load-sharing principles, yield strength, fatigue limit, and elastic modulus of spinal biomaterials; analyze factors governing pedicle screw pullout and trajectory selection (standard vs. CBT); optimize construct stiffness, rod diameter, and crosslink usage; and apply biomechanical strategies to prevent subsidence, screw pullout, rod breakage, and junctional breakdown.
• Biomaterials and Mechanical PropertiesBiomaterial selection dictates construct stiffness, fatigue life, and imaging compatibility. Commercially pure titanium and titanium alloys (Ti-6Al-4V) provide excellent biocompatibility, corrosion resistance, high fatigue strength, and an elastic modulus (110 GPa) closer to cortical bone than stainless steel (200 GPa) or cobalt-chromium (CoCr, 210–230 GPa), reducing stress shielding while causing minimal MRI artifact. Cobalt-chromium rods offer superior rigidity and maintain surgical sagittal correction in long adult deformity constructs but concentrate junctional stress. Polyetheretherketone (PEEK, modulus 3.6 GPa, close to cancellous bone) and porous 3D-printed titanium are widely used for interbody cages to minimize subsidence and promote direct osseointegration.
• Pedicle Screw Biomechanics and AnchoragePedicle screws provide the strongest biomechanical fixation by engaging all three spinal columns. Pullout strength and toggle resistance are governed by: 1) Screw outer diameter (the most critical factor, occupying 70–80% of inner pedicle width); 2) Screw length and depth of insertion (engaging 70–80% of vertebral body depth increases resistance by 20–30%); 3) Thread geometry (dual-lead, buttress, or conical core profiles); 4) Trajectory: the standard anatomical trajectory traverses the anatomical axis of the pedicle, whereas Cortical Bone Trajectory (CBT) screws employ a mediolateral, caudocranial path that engages high-density cortical bone of the lamina, pedicle wall, and superior vertebral border, increasing pullout strength in osteoporotic bone by over 30%; and 5) Bone mineral density (BMD): screw pullout strength correlates directly with DEXA T-scores.
• Rods, Connectors, and Multi-Rod ConstructsRods transmit axial, bending, and torsional loads across instrumented segments. Rod stiffness is proportional to the fourth power of its radius (Stiffness proportional to r^4); thus, increasing rod diameter from 5.5 mm to 6.35 mm increases bending stiffness by approximately 75%. In high-stress deformity applications (e.g., across pedicle subtraction osteotomies [PSO] or the lumbosacral junction), satellite, accessory, or delta multi-rod constructs distribute mechanical loads and substantially reduce rod fatigue fracture and nonunion rates. Transverse crosslinks increase torsional construct rigidity in long constructs (especially across thoracic kyphosis) but provide minimal resistance to flexion-extension forces.
• Interbody Cages and Anterior Column SupportThe anterior and middle columns normally support 80% of axial compressive loads (Dennis three-column model). Interbody cages (ALIF, LLIF, OLIF, TLIF, PLIF) reconstruct this anterior load-bearing column, sharing compressive loads with posterior pedicle screws and reducing posterior rod bending moments by up to 70%. Cage footprint, lordotic angle, and placement on the peripheral apophyseal ring (the densest structural zone of the vertebral endplate) are critical for preventing cage subsidence into the softer central cancellous bone.
• Instrumentation in the Osteoporotic SpineOsteoporosis severely compromises screw purchase, leading to premature loosening, windshield-wiper toggle, and pullout. Biomechanical strategies to enhance fixation include: using larger diameter screws, under-tapping the pedicle tract (by 1.0 mm), utilizing Cortical Bone Trajectory (CBT) screws, polymethylmethacrylate (PMMA) fenestrated screw cement augmentation, multi-level fixation constructs, bicortical purchase (in S1 or cervical spine), and supplementing with iliac or S2-alar-iliac (S2AI) pelvic screws across the lumbosacral junction.
• Clinical Application: Biomechanical construct design must balance rigidity with load sharing to foster bone healing. For short-segment degenerative instability (1–2 levels), titanium alloy 5.5 mm or 6.0 mm rods with interbody support provide ideal load sharing without over-stiffening. For long deformity constructs or 3-column osteotomies (PSO/VCR), CoCr rods or multi-rod (3-rod/4-rod) constructs with outrigger accessory rods are indicated to prevent rod fatigue fracture before fusion matures. In osteoporotic patients (DEXA T-score < -2.5), avoid relying solely on standard pedicle screws: utilize cement-augmented fenestrated screws, CBT screws, or extend instrumentation levels, ensuring that interbody cages span the dense peripheral cortical apophyseal ring bilaterally to eliminate subsidence. At construct terminations, avoid abrupt transitions in stiffness by using softer transition rods, ligamentous tethering, or prophylactic vertebroplasty at the upper instrumented vertebra (UIV/UIV+1) to prevent proximal junctional kyphosis (PJK) and vertebral compression fractures.
🏷️

Keywords

Preferred DeCS/MeSH Descriptors:
Spinal FusionBone ScrewsBiomechanical PhenomenaProstheses and ImplantsTitaniumPolyetheretherketoneMaterials TestingStress, Mechanical
⭐

Why this chapter matters

Every spinal implant alters load distribution across the vertebral column. A perfectly positioned screw can fail by fatigue in the setting of pseudarthrosis; an excessively rigid rod can correct severe deformity while causing catastrophic junctional fracture; and a high-tech interbody cage can subside into the vertebral body if undersized or placed off the apophyseal ring. This chapter translates mechanical engineering principles into concrete operative decisions, ensuring that construct design withstands physiological stresses and successfully achieves permanent biological fusion.

“Spinal instrumentation is a temporary mechanical bridge designed to maintain stability and alignment while biological fusion matures. Construct success depends on matching biomaterial stiffness (Ti, CoCr, PEEK), screw trajectory (standard vs. CBT), rod construct geometry (multi-rod), and anterior column load sharing (cages) to patient bone quality and biomechanical demands. Over-stiff constructs invite junctional failure, while inadequate constructs fail by fatigue before arthrodesis occurs.”
✨

Chapter Highlights

🌐
Card 1 — Core Concept
Instrumentation is a Load-Sharing Bridge

Spinal hardware must share load with the anterior column (interbody cage) and bone graft. Constructing anterior support offloads up to 70% of posterior rod stresses, preventing cyclic fatigue failure and rod breakage while promoting solid arthrodesis according to Wolff's law.

🩺
Card 2 — Clinical Decision
Optimize Purchase in Osteoporotic Bone

In patients with compromised bone mineral density (osteopenia/osteoporosis), utilize Cortical Bone Trajectory (CBT) screws, PMMA cement-augmented fenestrated screws, larger diameter screws, and wide-footprint interbody cages spanning the peripheral apophyseal ring to prevent pullout and subsidence.

📐
Card 3 — Key Pearl / Warning
Prevent Fatigue Fracture in High-Stress Zones

Across 3-column osteotomies (PSO) and the lumbosacral junction (L5–S1), standard 2-rod constructs face extreme cyclic bending moments leading to fatigue breakage. Always utilize multi-rod (3-rod or 4-rod) constructs and robust pelvic fixation (S2AI screws) to distribute loads.

📑

How to Cite this Chapter (Vancouver Format)

Official bibliographic indexing and citation guidelines
📖 Pages: 119-134Vancouver Style
Authors (Vancouver):Martins DE, Parreira MGC

Martins DE, Parreira MGC. Biomecânica dos implantes nas fixações vertebrais. In: Pudles E, Defino H, Risso M, editors. Tratado de Cirurgia da Coluna Vertebral (Treatise of Spine Surgery). 1st ed. Rio de Janeiro: Dilivros Editora; 2026. p. 119-134.

ISBN: 978-85-8053-292-0 • 1.ª Edição • Dilivros Editora
📚

Bibliographic References

1. Murugan SS. Mechanical properties of materials: definition, testing and application. Int J Mod Stud Mech Eng. 2020;6(2):28-38. doi:10.20431/2454-9711.0602003.
2. Ribeiro AMA, da Silva FS, Gomes JRA, de Andrade Silva J, Bártolo PJ, Oliveira AL. Biomaterials in orthopedic devices: current issues and future perspectives. Materials (Basel). 2022;15(10):3622. doi:10.3390/ma15103622.
3. Geetha M, Singh AK, Asokamani R, Gogia AK. Ti based biomaterials, the ultimate choice for orthopaedic implants: a review. Prog Mater Sci. 2009;54(3):397-425. doi:10.1016/j.pmatsci.2008.06.004.
4. Oladapo BI, Zahedi SA, Ismail SO, Omigbodun FT, Ikumapayi OM, Afolalu SA. 3D printing of PEEK and its composite to increase biointerfaces as a biomedical material: a review. Colloids Surf B Biointerfaces. 2021;208:111726. doi:10.1016/j.colsurfb.2021.111726.
5. Ruffilli A, Fiore M, Palumbo A, Barletta P, D’Amato R, Faldini C. 5.5-mm cobalt-chrome vs 6-mm titanium alloy rods in surgical treatment of Lenke 1 adolescent idiopathic scoliosis with high-density pedicle screws and direct vertebral rotation on differently shaped rods: a retrospective comparative cohort study. Global Spine J. 2022;12(6):1170-7. doi:10.1177/21925682211058997.
6. Dorozhkin SV. Bioceramics of calcium orthophosphates. Biomaterials. 2010;31(7):1465-85. doi:10.1016/j.biomaterials.2009.11.050.
7. Sobieraj MC, Rimnac CM. Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior. J Mech Behav Biomed Mater. 2009;2(5):433-43. doi:10.1016/j.jmbbm.2008.11.006.
8. Liljenqvist U, Hackenberg L, Link T, Halm H. Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. Acta Orthop Belg. 2001;67(2):157-63.
9. Wadhwa RK, Thakur JD, Khan IS, et al. Adjustment of suboptimally placed lumbar pedicle screws decreases pullout strength and alters biomechanics of the construct: a pilot cadaveric study. World Neurosurg. 2015;83(4):604-11. doi:10.1016/j.wneu.2014.04.065.
10. Wu LC, Hsieh YY, Tsuang FY, et al. Pullout strength of different pedicle screws after primary and revision insertion: an in vitro study on polyurethane foam. BMC Musculoskelet Disord. 2023;24:863. doi:10.1186/s12891-023-07015-3.
11. Matsukawa K, Yato Y, Imabayashi H. Impact of screw diameter and length on pedicle screw fixation strength in osteoporotic vertebrae: a finite element analysis. Asian Spine J. 2021;15(5):566-74. doi:10.31616/asj.2020.0353.
12. Cho W, Cho SK, Wu C. The biomechanics of pedicle screw-based instrumentation. J Bone Joint Surg Br. 2010;92(8):1061-5. doi:10.1302/0301-620X.92B8.24237.
13. Zamarioli A, Simões PA, Shimano AC, Defino HLA. Torque de inserção e resistência ao arrancamento dos parafusos vertebrais com alma cilíndrica e cônica. Rev Bras Ortop. 2008;43(10):452-9.
14. Shih KS, Hsu CC, Hou SM, Yu SC, Liaw CK. Comparison of the bending performance of solid and cannulated spinal pedicle screws using finite element analyses and biomechanical tests. Med Eng Phys. 2015;37(11):1091-6. doi:10.1016/j.medengphy.2015.06.008.
15. Ye B, Yan M, Zhu H, Duan W, Hu X, Ye Z, et al. Novel screw head design of pedicle screw for reducing the correction loss in the patients with thoracolumbar vertebral fractures: a biomechanical study. Spine (Phila Pa 1976). 2017;42(7):E379-84.
16. Liu MY, Tsai TT, Lai PL, Hsieh MK, Chen LH, Tai CL. Biomechanical comparison of pedicle screw fixation strength in synthetic bones: effects of screw shape, core/thread profile and cement augmentation. PLoS One. 2020;15(2):e0229328. doi:10.1371/journal.pone.0229328.
17. Vendrame JRB, Shimano AC, Kandziora F, Defino HLA. Estudo da influência do diâmetro do orifício piloto na resistência ao arrancamento do parafuso pedicular. Acta Ortop Bras. 2008;16(2):69-74. doi:10.1590/S1413-78522008000200001.
18. Kanno H, Onoda Y, Hashimoto K, Aizawa T, Ozawa H. Reinforcement of percutaneous pedicle screw fixation with hydroxyapatite granules in patients with osteoporotic spine: biomechanical performance and clinical outcomes. Medicina (Kaunas). 2022;58(5):579. doi:10.3390/medicina58050579.
19. Solitro GF, Amirouche F. Currently adopted criteria for pedicle screw diameter selection. Spine Deform. 2018;6(6):751-9. doi:10.1016/j.jspd.2018.06.007.
20. Coe JD, Vaccaro AR, Dailey AT, Skolasky RL Jr, Sasso RC, Ludwig SC, et al. Lateral mass screw fixation in the cervical spine: a systematic literature review. J Bone Joint Surg Am. 2013;95(23):2136-43. doi:10.2106/JBJS.L.01522.
21. Lee S, Cho DC, Roh SW, et al. Cervical alignment after posterior cervical fusion surgery: pedicle screw versus lateral mass screw fixation. Spine (Phila Pa 1976). 2021;46(10):E576-83. doi:10.1097/BRS.0000000000003845.
22. Jones EL, Heller JG, Silcox DH, Hutton WC. Cervical pedicle screws versus lateral mass screws: anatomic feasibility and biomechanical comparison. Spine (Phila Pa 1976). 1997;22(9):977-82. doi:10.1097/00007632-199705010-00009.
23. Soliman MAR, Aguirre AO, Khan S, et al. Complications associated with subaxial placement of pedicle screws versus lateral mass screws in the cervical spine (C2-T1): systematic review and meta-analysis comprising 4,165 patients and 16,669 screws. Neurosurg Rev. 2023;46(1):61. doi:10.1007/s10143-023-01968-8.
24. Heller JG, Silcox DH, Sutterlin CE. Complications of posterior cervical plating. Spine (Phila Pa 1976). 1995;20(6):2442-8.
25. Teologia AA, Burch S. Safety and efficacy of reconstructing complex cervical spine pathology using pedicle screws inserted with Stealth navigation and O-Arm-guided 3D technology. Spine (Phila Pa 1976). 2015;40(18):1397-406. doi:10.1097/BRS.0000000000001026.
26. Warburton A, Girdler SJ, Mikhail CM, Ahn A, Cho SK. Biomaterials in spinal implants: a review. Neurospine. 2020;17(1):101-10. doi:10.14245/ns.1938296.148.
27. Shega FD, Zhang H, Manini DR, Tang M, Liu S. Comparison of effectiveness between cobalt chromium rods versus titanium rods for treatment of patients with spinal deformity: a systematic review and meta-analysis. Adv Orthop. 2020;2020:8475910. doi:10.1155/2020/8475910.
28. Kovacı H, Yetim AF, Çelik A. Biomechanical analysis of spinal implants with different rod diameters under static and fatigue loads: an experimental study. Biomed Eng-Biomed Tech. 2018. doi:10.1515/bmt-2017-0236.
29. Bourghli A, Boissière L, Kieser D, et al. Multiple-rod constructs do not reduce pseudarthrosis and rod fracture after pedicle subtraction osteotomy for adult spinal deformity correction but improve quality of life. Neurospine. 2021;18(4):816-23. doi:10.14245/ns.2142596.298.
30. Dvorak MF, MacNab I, eds. Anterior cervical plate fixation: a biomechanical study to evaluate the effects of plate design, endplate preparation, and bone mineral density. Spine. 2005;30(3):294-301. doi:10.1097/01.brs.0000150813.51034.5e.
31. Kim SH, Kim JH, Kwon JW, Kim HS, Moon SH, Suk KS, Lee BH. Biomechanical advantage of pedicle screws over lateral mass screws in combined anterior-posterior cervical surgery: radiologic outcomes. J Clin Med. 2023;12(9):3201. doi:10.3390/jcm12093201.
32. Eck JC, Humphreys SC, Lim TH, Jeong ST, Kim JG, Hodges SD, et al. Biomechanical study on the effect of cervical spine fusion on adjacent-level intradiscal pressure and segmental motion. Spine. 2002;27(22):2431-4.
33. Ryken TC, Clausen JD, Traynelis VC, Goel VK. Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws. J Neurosurg. 1995;83(2):324-9. doi:10.3171/jns.1995.83.2.0324.
34. Brodke DS, Zdeblick TA, Kunz DN, McCabe R, Ogilvie JW. Anterior cervical fixation: analysis of load-sharing and stability with use of static and dynamic plates. J Bone Joint Surg Am. 2006;88(7):1566-73. doi:10.2106/JBJS.E.00305.
35. Alvi MA, Kerezoudis P, Wahood W, Wahood A, Elder BD, Bydon M. Titanium cages versus polyetheretherketone cages in interbody fusions: a meta-analysis of clinical and radiographic outcomes. Spine J. 2024;24(6):911-22. doi:10.1016/j.spinee.2024.05.009.
36. Hussain I, Konbaz FM, Ahmed SI, et al. Biomechanical stability analysis of a stand-alone cage, static and dynamic plate constructs in a two-level anterior cervical discectomy and fusion model. Orthop Surg. 2019;11(4):603-9.
37. Wang Y, Zhang K, Li Y, et al. Effects of new assembled titanium mesh cage on the improvement in biomechanical performance of single-level anterior cervical corpectomy and fusion: a finite element analysis. BMC Musculoskelet Disord. 2025;26:404.
38. Zhao Y, Yang S, Huo Y, Li Z, Yang D, Ding W. Locking stand-alone cage versus anterior plate construct in anterior cervical discectomy and fusion: a systematic review and meta-analysis based on randomized controlled trials. Eur Spine J. 2020;29(12):3122-35. doi:10.1007/s00586-020-06561-x.
39. Boer LFR, Zorzetto E, Yeh F, Wajchenberg M, Martins DE. Degenerative cervical disorder: stand-alone cage versus cage and cervical plate: a systematic review. Global Spine J. 2020;10(5):571-80. doi:10.1177/2192568219876288.
40. El Baz EA, Sultan AM, Barakat AS, et al. The use of anterior cervical interbody spacer with integrated fixation screws for management of cervical disc disease. SICOT J. 2019;5:4.
41. Ni S, Yang R, Liu S, et al. Biomechanical analysis of a newly designed and 3D printed plate-locking interbody cage: an observational study of finite element analysis. Sci Rep. 2025;15:3534.
42. Patwardhan AG, Havey RM. Biomechanics of cervical disc arthroplasty: a review of concepts and current technology. Int J Spine Surg. 2020;14(Suppl 2):S14-28. doi:10.14444/7087.
43. Lentz JM, Mun F, Suresh KV, Groves ML, Sponseller PD. How and when to use hooks to improve deformity correction. JPOSNA. 2021 Nov;3(4).
44. Ogura Y, Glassman SD, Sucato D, Hresko MT, Carreon LY. Incidence of proximal junctional kyphosis with pedicle screws at upper instrumented vertebrae in posterior spinal fusion for adolescent idiopathic scoliosis. Global Spine J. 2021;11(7):1019-24. doi:10.1177/2192568220935107.
45. Park SJ, Park JS, Kang DH, et al. Proximal junctional failure development despite achieving ideal sagittal correction according to age-adjusted alignment target in patients with adult spinal deformity: risk factor analysis of 196 cases undergoing low thoracic to pelvic fusion. Neurospine. 2024;21(4):1080-90. doi:10.14245/ns.2448734.367.
46. Helgeson MD, Shah SA, Newton PO, Clements DH, Betz RR, Marks MC, Bastrom T. Evaluation of proximal junctional kyphosis in adolescent idiopathic scoliosis following pedicle screw, hook, or hybrid instrumentation. Spine (Phila Pa 1976). 2010;35(2):177-81. doi:10.1097/BRS.0b013e3181c77f8c.
47. Canavese F, Samba A. Sublaminar polyester bands for the correction of idiopathic and neuromuscular scoliosis. Ann Transl Med. 2020;8(2):32. doi:10.21037/atm.2019.08.109.
48. Battista C, Wild C, Kreul S, Albert M. Prevention of proximal junctional kyphosis and failure using sublaminar bands in a hybrid construct in pediatric kyphosis deformity. Int J Spine Surg. 2018;12(6):644-9. doi:10.14444/5080.
49. Park BJ, Gold CJ, Christianson D, DeVries Watson NA, Nourski KV, Woodroffe RW, Hitchon PW. Biomechanical assessment of the effect of sublaminar band tensioning on lumbar motion. J Neurosurg Spine. 2022;37(6):836-42. doi:10.3171/2022.5.SPINE22371.
50. Gibbs D, Grossbach AJ, Mallory N, Toop N, Viljoen S. Delayed stenosis associated with sublaminar band placement in the thoracic spine for proximal junctional kyphosis. Surg Neurol Int. 2023;14:211. doi:10.25259/SNI_375_2022.
51. Cadieux C, Brzozowski P, Fernandes RJR, McGregor ME, Zdero R, Bailey CS, et al. Topping-off a long thoracic stabilization with semi-rigid constructs may have favorable biomechanical effects to prevent proximal junctional kyphosis: a biomechanical comparison. Global Spine J. 2025;15(3):1685-94. doi:10.1177/21925682241259695.
52. Liu SX, Feng AP, Zeng TH, Jhang SW, Chen CM, He LR, et al. 3Dprinted porous titanium versus polyetheretherketone cages in lateral lumbar interbody fusion: a systematic review and meta-analysis of subsidence. Front Med (Lausanne). 2024;11:1389533. doi:10.3389/fmed.2024.1389533.
53. Patel NA, O’Bryant S, Rogers CD, Boyett CK, Chakravarti S, Gendreau J, et al. Three-dimensional-printed titanium versus polyetheretherketone cages for lumbar interbody fusion: a systematic review of comparative in vitro, animal, and human studies. Neurospine. 2024;21(3):764-78. doi:10.14245/ns.2346244.122.
54. Akpolat Y, Görgülü FF, Kizmaz M, Acaroglu E. Does the application of expandable cages in TLIF provide improved clinical and radiological results compared to static cages? A meta-analysis. Front Surg. 2022;9:949938. doi:10.3389/fsurg.2022.949938.
Episode 06 – Early-Onset Scoliosis
Scheduled Premiere
Exclusive Premiere • Wednesday, October 07 at 9:00 PM (BRT)
Wednesday, October 07 at 9:00 PM (BRT)
The live countdown will be activated on the eve of the premiere.

The full videocast will premiere automatically in this player on Wednesday, 10/07 at 6:00 PM (BRT).

Also premiering on Spotify
Treatise in Debate

Official videocast derived from the treatise chapters.

Episode 06 – Early-Onset Scoliosis

Lungs and the Growing Spine: thoracic development, C-EOS classification, and growth-friendly surgical techniques